When operating in matrix mode
| Power Source | Usable power supply unit: AD-011, AD-031B 24 V DC (operational range: 20 V – 40 V DC) Two power inputs construction enables dual-redundant power supply. |
| Current Consumption | 0.34 A or less (maximum value in the power operating range) 0.29 A or less (when operated on 24 V DC) |
| Indication | Control input indicator (32), Power indicator, CPU OFF indicator, FAULT indicator |
| Control Output | 32 outputs, no-voltage make contact output, relay contact output (withstand voltage: 40 V DC, control current: 2 mA to 300 mA), removable terminal block (6 pins) |
CI/CO Link
| Input/Output Connector | Input: 1 input, Output: 1 output RJ45 Connector |
| Connection Cable | Shielded Category 5 twisted pair cable (CAT5-STP) (1 pair of data wire + 1 pair of control wire) |
| Maximum Cable Distance | 800 m (874.89 yd) |
| Operating Temperature | 0 ℃ to +40 ℃ (32 ゜F to 104 ゜F) |
| Operating Humidity | 35 % to 80 %RH (no condensation) |
| Finish | Panel: Aluminum, black, alumite Case: Surface-treated steel plate |
| Dimensions | 482 (W) × 44 (H) × 331.5 (D) mm (18.98 × 1.73″ × 13.05″)” |
| Weight | 3.6 kg (7.94 lb) |
| Accessory | Removable terminal plug (16 pins) …4, Removable terminal plug (4 pins) …1, Removable terminal plug (2 pins) …1, Rack mounting screw …4 |
When operating in stand-alone mode
Conductor diameter of the main cable vs. maximum cable length (when the RM-200RJ is used)
| Conductor diameter | Maximum Cable Distance |
| “%%c0.65 mm (%%c0.026)””” | 160 m (175.04 yd) |
| ” %%c0.9 mm (%%c0.035)””” | 320 m (350.08 yd) |
| “%%c1.2 mm (%%c0.047)””” | 570 m (623.58 yd) |
| ” %%c0.9 mm (%%c0.035) AWG 16 × 3 pairs CPEV (2 pairs for DC and 1 pair for data)””” | 640 m (700.16 yd) |
| “%%c1.2 mm (%%c0.047) AWG 16 × 3 pairs CPEV (2 pairs for DC and 1 pair for data)””” | 800 m (875.20 yd) |